5.5.10. Description of reply code
When executing the frequency setting (RYnD) or instruction code execution (RYnF), check the
reply code (RWr (n+2), (n+10), (n+14), (n+16), (n+18)) in the remote register after execution.
Reply code
Data
(Hexadecimal No.)
Item Description
0000H Normal (No error)
Normal completion of instruction code
execution.
0001H Write mode error
Parameter write was attempted during operation
other than a stop.
0002H
Parameter selection
error
Unregistered code number was set.
0003H Setting range error Set data is outside the setting data range.