December, 1998
ICC #10160-001
HIGH PERFORMANCE TRANSISTOR INVERTER
TRUE TORQUE CONTROL DRIVE SERIES
PROFIBUS-DP COMMUNICATIONS INTERFACE
Vista de página 0
1 2 3 4 5 6 ... 61 62

Resumo do Conteúdo

Página 1 - ICC #10160-001

December, 1998 ICC #10160-001 HIGH PERFORMANCE TRANSISTOR INVERTER TRUE TORQUE CONTROL DRIVE SERIES PROFIBUS-DP COMMUNICATIONS INTERFACE

Página 2 - Introduction

9 8. Install the Profibus network cable through the access holes at the bottom of the inverter and route the cable in order to make connections to

Página 3 - Usage Precautions

1013. If a ground cable is being used, connect the ground cable to the selected ground point. 14. Reinstall the inverter’s cover (close and latch th

Página 4 - TABLE OF CONTENTS

112.32.32.32.3 RemovalRemovalRemovalRemoval Removal of the Profibus interface board from a TOSVERT-130 G3 inverter should only be performed by

Página 5

125. CAUTION! The option ROM PCB and Profibus interface board are static-sensitive devices. Standard electrostatic-sensitive component handling

Página 6

1310. Reinstall the inverter’s cover (close and latch the door on units with hinged doors). DANGER! Do not operate unit with the cover off / cab

Página 7

143.3.3.3. GroundingGroundingGroundingGrounding Grounding is of particular importance for reliable, stable operation. Communication system ch

Página 8

155.5.5.5. Maintenance And InspectionMaintenance And InspectionMaintenance And InspectionMaintenance And Inspection Preventive maintenance and

Página 9

166.6.6.6. Storage And WarrantyStorage And WarrantyStorage And WarrantyStorage And Warranty 6.16.16.16.1 StorageStorageStorageStorage Ob

Página 10

177.7.7.7. G3 Parameter SettingsG3 Parameter SettingsG3 Parameter SettingsG3 Parameter Settings Profibus interface board communications are en

Página 11

188.8.8.8. Feature SummaryFeature SummaryFeature SummaryFeature Summary The Toshiba Profibus-DP interface provides a wide array of network dat

Página 12

1Introduction Thank you for purchasing the “Profibus-DP Communications Interface” for the Toshiba TOSVERT-130 G3 High-Performance Transistor Invert

Página 13

19Indicators 1 green LED is provided to indicate when the interface has achieved the DATA_EXCHANGE state with the network master. This serves as a

Página 14

209.9.9.9. Exchanged Data StructuresExchanged Data StructuresExchanged Data StructuresExchanged Data Structures 9.19.19.19.1 Output (Contro

Página 15

21 Table 1 : Command Word Format Bit Function Setting 0 RUN command 0: Stop 1: Run 1 STOP Command (has priority over RUN command) 0: run enabl

Página 16

229.29.29.29.2 Input (Status) Data FormatInput (Status) Data FormatInput (Status) Data FormatInput (Status) Data Format The input data structu

Página 17

23In order to determine the drive’s actual output frequency, the data contained in the output frequency word (offsets 2 and 3) must first be convert

Página 18

24 Table 3 : Input Terminal Monitor Word Format Bit Terminal Value 0 F 0: Terminal – CC open 1: Terminal – CC shorted 1 R 0: Terminal – CC op

Página 19

2510.10.10.10. Parameter Register Parameter Register Parameter Register Parameter Register AccessAccessAccessAccess 10.110.110.110.1 Parame

Página 20

2610.210.210.210.2 Parameter Number / Action Input WordsParameter Number / Action Input WordsParameter Number / Action Input WordsParameter Numbe

Página 21 - Offset Data Explanation

2710.310.310.310.3 Parameter Access ProcedureParameter Access ProcedureParameter Access ProcedureParameter Access Procedure In order to read f

Página 22

28•= If an error occurred during the read or write request, this will be indicated to the master by Resp1:Resp0 changing from 0:0 to 1:1. The param

Página 23

2Usage Precautions •= Please use the interface only when the ambient temperature of the inverter unit into which the interface is installed is with

Página 24

2911.11.11.11. Parameter RegistersParameter RegistersParameter RegistersParameter Registers How To Use This Section: This section contains ta

Página 25

30 Example Table Excerpt: Register Function / Title Bank Mask Adjustment Range Multiplier 26 MAXIMUM OUTPUTFREQUENCY (∗∗∗∗)0 / 1 FFFF 0BB8 ∼

Página 26 - 15 12 11 8 7 4 3 0

3111.111.111.111.1 ReadReadReadRead----Only RegistersOnly RegistersOnly RegistersOnly Registers Register Bit Function Bank Mask Adjustment

Página 27

32(Note 3) If the input / output power units data is 0, the monitored data is in 0.01kW units, and the multiplier is 0.01. If the input / output p

Página 28

3311.211.211.211.2 Read/Write Registers Read/Write Registers Read/Write Registers Read/Write Registers 11.2.111.2.111.2.111.2.1 GROUP:FUN

Página 29

3411.2.211.2.211.2.211.2.2 GROUP:FUNDAMENTAL PARAMETERS #2GROUP:FUNDAMENTAL PARAMETERS #2GROUP:FUNDAMENTAL PARAMETERS #2GROUP:FUNDAMENTAL PARAME

Página 30

3511.2.411.2.411.2.411.2.4 GROUP:TERMINAL SELECTION PARAMETERSGROUP:TERMINAL SELECTION PARAMETERSGROUP:TERMINAL SELECTION PARAMETERSGROUP:TERMIN

Página 31

36 Register Function / Title Bank Mask Adjustment Range Multiplier 60 “OUT” CONTACTS HOLDTIME0 / 1 00FF 0001 ∼ 0064 (1 ∼ 100) 1 61 LOW SPEED S

Página 32

37Table 7: Input Terminal Selections Setting Value Data (Hex) Function Setting Value Data (Hex) Function 0 10C8 R (reverse run) 28 04AF Binar

Página 33

38Table 8: Output Terminal Selections (RCH, LOW, FL, OUT relay contacts) Setting Value Data (Hex) Function Setting Value Data (Hex) Function 0 000

Página 34

3TABLE OF CONTENTS 1. Interface Board Diagram...5 2. Interface Board Instal

Página 35

3911.2.511.2.511.2.511.2.5 GROUP:SPECIAL CONTROL PARAMETERS GROUP:SPECIAL CONTROL PARAMETERS GROUP:SPECIAL CONTROL PARAMETERS GROUP:SPECIAL CON

Página 36

4011.2.611.2.611.2.611.2.6 GROUP:FREQUENCY SETTING PARAMETERSGROUP:FREQUENCY SETTING PARAMETERSGROUP:FREQUENCY SETTING PARAMETERSGROUP:FREQUENCY

Página 37

41 Register Function / Title Bank Mask Adjustment Range Multiplier 98 BINARY INPUT STD ORADJUSTABLE0 / 1 0001 0000: Standard (0) 0001: Adjus

Página 38

42 Register Function / Title Bank Mask Adjustment Range Multiplier 10F 8 or higher PRESET SPEED#8 FREQUENCY1 FFFF LL ∼ UL 0.01 110 PRESET SPEE

Página 39

4311.2.711.2.711.2.711.2.7 GROUP:PROTECTION FUNCTION PARAMETERSGROUP:PROTECTION FUNCTION PARAMETERSGROUP:PROTECTION FUNCTION PARAMETERSGROUP:PRO

Página 40

44 Register Function / Title Bank Mask Adjustment Range Multiplier 135 UNDERVOLTAGE TRIPSELECTION0 / 1 0080 0000: Trip disabled (0) 0080: Tr

Página 41

4511.2.811.2.811.2.811.2.8 GROUP:PATTERN RUN CONTROL PARAMETERSGROUP:PATTERN RUN CONTROL PARAMETERSGROUP:PATTERN RUN CONTROL PARAMETERSGROUP:PAT

Página 42

46 Register Function / Title Bank Mask Adjustment Range Multiplier 169 PATTERN GROUP #4SPEED #01 00FF 0000: Skip (0) 1 16A PATTERN GROUP #4SP

Página 43

47 Register Function / Title Bank Mask Adjustment Range Multiplier 182 SPEED #9 CONTINUEMODE1 00FF Same as SPEED #1 CONTINUEMODE  183 < 4S

Página 44

4811.2.911.2.911.2.911.2.9 GROUP:FEEDBACK CONTROL PARAMETGROUP:FEEDBACK CONTROL PARAMETGROUP:FEEDBACK CONTROL PARAMETGROUP:FEEDBACK CONTROL PARA

Página 45

411.2.7 GROUP:PROTECTION FUNCTION PARAMETERS...43 11.2.8 GROUP:PATTERN RUN CONTROL PARAMETERS...45

Página 46

4911.2.1011.2.1011.2.1011.2.10 GROUP:COMMUNICATION SETTING PARAMETERSGROUP:COMMUNICATION SETTING PARAMETERSGROUP:COMMUNICATION SETTING PARAMETER

Página 47

50 Register Function / Title Bank Mask Adjustment Range Multiplier 211 TOSLINE-S20 COMMERROR MODE1 0002 0000: Data cleared (0) 0002: Data re

Página 48

5111.2.1211.2.1211.2.1211.2.12 GROUP:UTILIGROUP:UTILIGROUP:UTILIGROUP:UTILITY PARAMETERSTY PARAMETERSTY PARAMETERSTY PARAMETERS Register Fun

Página 49

52 Register Function / Title Bank Mask Adjustment Range Multiplier 22D ACC/DEC TIME UNITSSELECTION0 / 1 0004 0000: 0.1 sec. (0) 0004: 0.01 s

Página 50

5311.2.1311.2.1311.2.1311.2.13 GROUP:MOTOR RATING PARAMETERSGROUP:MOTOR RATING PARAMETERSGROUP:MOTOR RATING PARAMETERSGROUP:MOTOR RATING PARAMET

Página 51

54 Table 9: Inverter Typeform Codes 230v Class 460v Class 600v Class Inverter Model Typeform Data (Hex) Inverter Model Typeform Data (Hex) Inver

Página 52

5511.311.311.311.3 Inverter Fault CodesInverter Fault CodesInverter Fault CodesInverter Fault Codes LCD Display Message Data (Hex) Explanati

Página 53

56 LCD Display Message Data (Hex) Explanation CURRENT DETECT ERROR(PRESS CLEAR)××1A Output current detection circuit error OPTION PCB ERROR(PRESS C

Página 54

5712.12.12.12. GSD FileGSD FileGSD FileGSD File The following is a copy of the G3 Profibus interface card’s GSD file, which is used for networ

Página 55

58Sync_Mode_supp = 1Auto_Baud_supp = 1Set_Slave_Add_supp = 1Min_Slave_Intervall = 1;Modular_Station = 0Max_Module = 1Max_Input_Len = 16Max_Output_Le

Página 56

51.1.1.1. Interface Board DiagramInterface Board DiagramInterface Board DiagramInterface Board Diagram Plated SHIELD connection poi

Página 57

5913.13.13.13. NotesNotesNotesNotes

Página 59

TOSHIBA INTERNATIONAL CORPORATIONINDUSTRIAL DIVISION13131 West Little York Rd., Houston, TX 77041Tel: [800] 231-1412 Fax: [713] 466-8773 Telex: 7620

Página 60

62.2.2.2. Interface Board Installation / RemovalInterface Board Installation / RemovalInterface Board Installation / RemovalInterface Board Insta

Página 61

7•= Setting the standard mode selection parameter will be referred to in this manual as performing a TYPE X RESET, where X is the parameter setting

Página 62 - INDUSTRIAL DIVISION

8 6. CAUTION! The option ROM PCB assembly and interface board are static-sensitive devices. Standard electrostatic-sensitive component handling p